26 Orion LT Weather Station
________________________________________________________________________________________________________________________
Connecting the Sensor Transmitter to the Interface Module
Attach the wires from the end of the sensor cable to the terminal block screws on the Interface Module as
follows:
Standard
Heated
Signal
Color
Color
1 +12 V RED RED and Brown
2 GND White and Bare White, Blue, and Bare
3 N/C No connection No connection
4 GND Green Green
5 RX Black Black
6 TX Orange Orange