USER'S GUIDE Vaisala HUMICAP® Hand-Held Moisture and Temperature in Oil MeterMM70 M210498EN-C
USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 8 ______________
Chapter 2 _____________________________________ PRODUCT OVERVIEW AND MECHANICS CHAPTER 2 PRODUCT OVERVIEW AND MECHANICS Vaisala´s Hand-held MM70 Devi
USER'S GUIDE____________________________________________________________________ Structure of the MI70 Indicator 0605-094 Figure 1 MI Indic
Chapter 2 _____________________________________ PRODUCT OVERVIEW AND MECHANICS Structure of the MMP78 Probe 0605-087 Figure 2 MMP78 Probe The follo
USER'S GUIDE____________________________________________________________________ Display Parameters - aw: water activity - T: temperature (°C/
Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS CHAPTER 3 INSTALLATION AND MOUNTING OPTIONS Installing and Rechargin
USER'S GUIDE____________________________________________________________________ 2. Press the power on/off key. 3. Select the language by usi
Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS measurements in pipelines. The maximum installation pressure is 10 ba
USER'S GUIDE____________________________________________________________________ 0605-080 Figure 5 Tightening Clasp Nut The following numbers
Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS 0605-083 Figure 6 Sealing Thread Cutting for the Fitting Body CAUT
PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages at ht
USER'S GUIDE____________________________________________________________________ 3. Make sure that the temperature at the measurement point is
Chapter 3 ____________________________________ INSTALLATION AND MOUNTING OPTIONS NOTE The probe can be installed in the process through the ball valve
USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 20 ____________
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS CHAPTER 4 MENU OPERATIONS AND SETTINGS Function Keys and Menu Structu
USER'S GUIDE____________________________________________________________________ - To turn the indicator on or off, press the power On/Off key.
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS Function keys are shortcuts to some functions or menus. Shortcuts for
USER'S GUIDE____________________________________________________________________ Settings Display Settings 0605-102 Figure 11 Display Sett
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 1. Open the MENU. First press the right arrow key, and then press the
USER'S GUIDE____________________________________________________________________ 1. Open the MENU. First press the right arrow key, and then pre
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS Selecting Language You can select any of the following languages for
________________________________________________________________________________ Table of Contents CHAPTER 1 GENERAL INFORMATION...
USER'S GUIDE____________________________________________________________________ Changing the Shorcut Keys As a default, the function keys are s
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 3. Select Date and Time. Press the right arrow key. 4. To change th
USER'S GUIDE____________________________________________________________________ 0605-099 Figure 14 Device Information Submenus Restoring Fac
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS If additional accuracy is needed, more information is found below in
USER'S GUIDE____________________________________________________________________ 7. Select the B value (B:0.0000) and press the SET key. 8. Se
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS MM70 alarms by beeping and blinking the backlight. The alarm turns on
USER'S GUIDE____________________________________________________________________ Selecting and Scaling the Analog Output 0605-093 Figure 17 A
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 7. Select 0.0 V to set the value for the 0.0 V output signal, press t
USER'S GUIDE____________________________________________________________________ 2. Connect the DMP70/GMP70/HMP70 probe to the other connector p
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS 8. Start recording: Select Start/Stop recording, press the START key.
USER'S GUIDE____________________________________________________________________ Rounding ...
USER'S GUIDE____________________________________________________________________ Viewing Recorded Data 1. Open the MENU. First press the right a
Chapter 4 _________________________________________ MENU OPERATIONS AND SETTINGS Transferring Recorded Data to PC The recorded data can be transferred
USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 40 _____________
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT CHAPTER 5 CALIBRATION AND ADJUSTMENT General Notes about Calibration
USER'S GUIDE____________________________________________________________________ Calibration and Adjustment of HMP228 Series Transmitters You ca
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 0605-091 Figure 19 Adjustment Mode Relative Humidity Adjustment by
USER'S GUIDE____________________________________________________________________ 4. Wait until the reading is stabilized (takes about 30 minute
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 10. Enter the second reference humidity value by using the arrow key
USER'S GUIDE____________________________________________________________________ 1. Select aw, RH, T or H2O (H2O can only be checked, not adjust
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 8. Adjustment is done. To return to the basic display, first press t
________________________________________________________________________________ Preparations before the Calibration ...
USER'S GUIDE____________________________________________________________________ Calibration and Adjustment of MMT330 Transmitters You can check
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 2. Check that the probes are located in equal conditions and wait un
USER'S GUIDE____________________________________________________________________ 2-point Adjustment by Using a Calibrator When using this adjust
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT Calibration and Adjustment of MM70 Series Probes General about Calib
USER'S GUIDE____________________________________________________________________ have to feed the reference values, the MM70 displays the accura
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 14. Confirm the adjustment, press the YES key (by pressing the NO ke
USER'S GUIDE____________________________________________________________________ 1-point Adjustment When using this adjustment method, start wit
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT 8. Calibration is done. To return to the basic display, first press
USER'S GUIDE____________________________________________________________________ NOTE If the oil sample is very dry and the temperatures are cl
Chapter 5 ___________________________________________ CALIBRATION AND ADJUSTMENT NOTE If the oil sample is very dry, and the temperatures are close t
USER'S GUIDE____________________________________________________________________ Figure 15 Measurement Setting Menus...
USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 58 _____________
Chapter 6 ___________________________________________________________ MAINTENANCE CHAPTER 6 MAINTENANCE Changing the Filter and Sensor 1. Screw out t
USER'S GUIDE____________________________________________________________________ Changing the Battery A new rechargeable battery pack can be or
Chapter 6 ___________________________________________________________ MAINTENANCE Vaisala Service Centers VAISALA __________________________________
USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 62 _____________
Chapter 7 ______________________________________________ TECHNICAL SPECIFICATIONS CHAPTER 7 TECHNICAL SPECIFICATIONS Measured Variables Water Activity
USER'S GUIDE____________________________________________________________________ MMP78 Probe Humidity sensor HUMICAP Temperature sensor Pt 100
Chapter 7 ______________________________________________ TECHNICAL SPECIFICATIONS Accuracy 0.2 % full scale Temperature dependence 0.002 %/ C full s
USER'S GUIDE____________________________________________________________________ Options and Accessories Available Table 3 List of Options and
Chapter 7 ______________________________________________ TECHNICAL SPECIFICATIONS Dimensions in mm (inches) Figure 21 MI70 Indicator VAISALA _______
Chapter 1 __________________________________________________ GENERAL INFORMATION CHAPTER 1 GENERAL INFORMATION About This Manual This manual provides
USER'S GUIDE____________________________________________________________________ Adjustment range 250m m340 (13.39)190 (7.48)170 (6.69)13.5 (0.
______________________________________________________ TECHNICAL SPECIFICATIONS VAISALA ______________________________________________________________
USER'S GUIDE____________________________________________________________________ To make sure you are not delivering high static voltages yourse
Chapter 1 __________________________________________________ GENERAL INFORMATION Warranty Vaisala hereby represents and warrants all Products manufact
Bedienungsanleitungen und Benutzerhandbücher für Auto-Kits Parrot CK-3400.
Wir stellen 1 PDF-Handbücher Parrot CK-3400 zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Datenblatt

11
12
15
15
20
20
22
23
26
26
34
36
37
45
48
48
53
59
64
64
70
70
77
| Modelle | Dokumententyp |
|---|---|
| 3200LS |
Datenblatt
Parrot 3200,
2 Seiten
|
| Minikit + |
Betriebsanweisung
Parrot Minikit +,
15 Seiten
|
| PC000025AA |
Handbuch
Parrot PC000025AA car kit,
3 Seiten
|
| MKi9000 |
Betriebsanweisung
Parrot MKi9000,
23 Seiten
|
| MKi9000 |
Betriebsanweisung
Parrot MKi9000,
23 Seiten
|
| PC000026AA |
Handbuch
Parrot PC000026AA car kit,
3 Seiten
|
| CK3200 LS-COLOR |
Spezifikationen
Parrot CK3200 LS-COLOR,
2 Seiten
|
| Minikit + |
Betriebsanweisung
Parrot Minikit +,
15 Seiten
|
| PC000054AA |
Handbuch
Parrot PC000054AA car kit,
3 Seiten
|
| RKi8400 |
Betriebsanweisung
Parrot RKi8400,
35 Seiten
|
| MKI-9200 |
Betriebsanweisung
Parrot MKI-9200,
35 Seiten
|
| PC000053AA |
Handbuch
Parrot PC000053AA car kit,
3 Seiten
|
| MKi9200 |
Betriebsanweisung
Parrot MKi9200,
32 Seiten
|
| MINIKIT |
Betriebsanweisung
Parrot MINIKIT,
144 Seiten
|
| PC000008AA |
Handbuch
Parrot PC000008AA car kit,
2 Seiten
|
| PC000031AA |
Handbuch
Parrot PC000031AA car kit [en] ,
3 Seiten
|
| PC000021AA |
Handbuch
Parrot PC000021AA car kit,
3 Seiten
|
| PC000027AA |
Handbuch
Parrot PC000027AA car kit,
3 Seiten
|
| MKi9100 |
Betriebsanweisung
Parrot MKi9100,
26 Seiten
|
| MKI-9100 |
Betriebsanweisung
Parrot MKI-9100,
30 Seiten
|
Comments to this Manuals