CHAPTER 4_____________________________________________________________ COMMISSIONING
VAISALA _________________________________________________________________________ 11
CHAPTER 4 COMMISSIONING
TABLE 4-1summarizes the commands used to commission the PTB220
series digital barometers. The commands are not case sensitive except
for the SCOM command.
TABLE 4-1 Commissioning commands
Function Command
sending mode SMODE
measurement mode MMODE
pulse mode settings PULSE
serial bus settings SERI
echo on / off ECHO
output format FORM
pressure resolution FORM
pressure trend FORM
pressure tendency FORM
error status FORM
stability indicator FORM
checksum FORM
height of height correction HHCP
error output format EFORM
display format DFORM
pressure and temperature units UNIT
averaging time AVRG
setting output interval INTV
address of the barometer ADDR
user specific SEND command SCOM
pressure stability indicator PSTAB
pressure alarm levels (HI and LO) PLARM
pressure difference limit PDMAX
keyboard locking KEYLOCK
The commissioning commands can be divided in two sections: the
operating mode commands and the software setting commands.