66.3
60
60
Ø 4.2
66.7
85.3
83.4
85.2
R2.1
124
120.9
25.8
84
R3.5
Technical Data
Performance
CO
2
-measurement range 0 ... 2000 ppm
0.....5000 ppm
Accuracy (including repeatability, non-
linearity and calibration uncertainty)
±(2 % of range + 2 % of
reading)
Long-term stability ± 5 % of range/5 years
Response time T90 1 min
Temperature dependence, typical -0,35 % of reading / °C
Pressure dependence, typical +0,15 % of reading/hPa
Warm-up time 1 min, 10 min for full.
specification
Product lifetime > 10 years
Operating Environment
Temperature -5 ... +45 °C (23 ... 113 °F)
Humidity 0 ... 85 %RH
Pressure 700 ... 1200 hPa
Electromagnectic compatibility
Complies with EMS standard EN61326-1, Generic Environment
Inputs and Outputs
Operating voltage 24 V (±20 %) AC/DC
Power consumption <2 W
Outputs 4 … 20 mA, 0 … 10 V,
RS-485, 2-wire, non-isolated
Housing
Material: ABS plastics
Colour: Cycolac 233599/NCS 0502-G50Y
Fire resistance: UL94 HB
Ingress protection: IP30
Dimensions
Dimensions in mm
Ref. B210568EN-E ©Vaisala 2012
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.