Soil Temperature Sensors
QMT103
The QMT103 soil/water temperature sensor has a ready-made cable
and a connector. Connect the signal cable to an available receptacle
(for example Soil T1) at the bottom of the equipment enclosure (see
section Connecting Cables on page 129).
9901-012
Figure 96 QMT103 Soil/Water Temperature Sensor
QMT107
During a typical installation, QMT107 probe is pressed into pre-
formed holes, but they can also be placed into excavated holes that are
then filled. On hard or rocky ground, a pilot hole is pre-formed with
an auger rod. Drill a hole according to the following procedure:
1. Choose a desired location for the probe. Assure that probe holes
are located within cable length of the logging unit.
2. Drill a hole into the ground with the auger held as straight as
possible. After you have drilled about 20 cm, extract the auger
from the hole.