Vaisala WAA151 Installation Manual Page 115

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 114
Chapter 4 ________________________________________________________________ Installation
VAISALA _______________________________________________________________________ 113
Fuel Moisture Sensor
CAUTION
It is important to keep the wooden dowel part of the sensor clean.
Avoid touching the dowel with bare hands. Any contact with grease
or oil will prevent the sensor from exchanging moisture and will
make the calibration invalid.
QFM101 Fuel Moisture Sensor uses two analog channels of the
logger: one for the temperature measurement and another for the
moisture measurement. Moisture is measured via one of the channels
CH1 to CH3. You should connect the sensor cable to the appropriate
channel. Temperature is measured with one of the channels CH4 to
CH7 and therefore you should modify the wiring as instructed below.
You should install the QFM101 sensor 30 cm above the forest floor
and orient the sensor parallel to the ground. The mounting bracket (1
in Figure 109 below) is not included in the sensor delivery. A rubber-
lined ring clamp (3) and the screw (4) are included with the sensor in
the package. To install the sensor, follow the procedure below:
1. Slide the ring clamp (3) onto the sensor body (2) and connect
the cable to the sensor.
2. Turn the sensor so that the two wire loops imbedded in the
wooden dowel will be horizontal. That is, the wires must be on
the sides of the sensor, not the top and bottom. Tighten the
clamp with the screw (4).
0201-041
Figure 109 Installing the Sensor with the Clamp
Page view 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 132 133

Comments to this Manuals

No comments