Chapter 3 __________________________________________________________ Selecting Location
VAISALA ________________________________________________________________________ 69
The following numbers refer to Figure 59 on page 68:
1 = Cable to MAWS
2 = Water level
3 = Sensor level
4 = Local reference
5 = Common level
Typically, the water level sensor is installed in a stilling well or inside
a pipe for protecting the sensor against debris and vandalism.
Placement of DCU7110
Place the sensor according to the Figure 60 below. The water level is
then calculated from the formula:
h1 = H - h2
where
H = Offset to common level
h2 = Measured distance
0202-007
Figure 60 DCU7110 Placement over Water