Installation Manual __________________________________________________________________
112 __________________________________________________________________ M010114en-B
1. Install the sensor as explained in Figure 105 on page 111, Figure
106 on page 111, and Figure 107 on page 111.
2. Pull the sensor cable close to the equipment enclosure. Cut the
cable to a proper length. Thread the cable through the connector
parts in the indicated order 1-2-3-4 (see Figure 87 on page 96).
3. Strip the sensor cable wires and connect them to connector
terminals according to Table 17 below. Assemble the connector.
Table 17 Cable Pins of QLW101 Leaf Wetness Sensor
Pin Number Wire Color Signal
1Red Supply, +
2 White Signal HI
3 Black (two wires) Supply, -
4. Connect the signal cable to an available receptacle (for example
CH3) at the bottom of the equipment enclosure (see section
Connecting Cables on page 129).
5. Open the enclosure's door and locate the logger.
6. Remove the connector from the input channel at the logger, for
example, CH3. The exact channel depends on your
configuration. Insert adapter QLA001 to the channel and place
the connector on top of it (see Figure 108 below).
0201-040
Figure 108 Adapter Installed to Connector