Chapter 5 _______________________________________________________________Maintenance
VAISALA _______________________________________________________________________ 147
QMT107
When the probe is extracted, clean the dirt accumulation on the
probe's surface with a soft cloth or sponge using water and mild
detergent. Field repairs are accomplished by replacing the complete
probe.
Soil Moisture Sensor
The ML2x probe is sealed after the factory calibration. It does not
require any routine maintenance and it is constructed of materials
selected for robust field operation. If the measurement rods become
bent in use, they can be carefully unscrewed from the body and
straightened. They have a right-handed thread. Please pay special
attention to the following points:
- Do not remove the cross-head sealing screws. This may damage the
seal and will invalidate your guarantee. No internal maintenance or
repair shall be performed by the user.
- Do not remove the probe from soil by pulling on the cable.
- Do not attempt to straighten the measurement rods while they are
still attached to the probe body. This may break the rods or damage
the case seal.
Water Level Sensors
QMV101/QMV102
To ensure reliable and accurate measurements, we recommend that
during each visit to the QMV101 Water Level Sensor the following
checks be made:
1. Check the drying detergent through the window of the junction
box.
2. If the drying detergent has turned red, change the cartridge. The
cartridge has reached its internal maximum absorption of
humidity. Replace the cartridge and adjust the interval for the
next visit.