Chapter 2 ___________________________________________________________Product Overview
VAISALA ________________________________________________________________________ 25
0105-003
Figure 5 QMC102 Memory Expansion Board
The data is logged into the daily files making it easy to locate and
download any particular data set for further analysis.
Currently there are cards available from 32 MB up to 280 MB. These
cards can be read directly in the PC. Several different types of readers
are commercially available: internal PCMCIA reader as well as
external readers to be connected to USB or parallel port of a PC.
0105-004
Figure 6 Compact Flash Memory Card Readers
Power Supplies
MAWS is a low-power system. The QML102 logger consumes only
less than 10 mA from a 6 V battery. It can be powered using a solar
panel or optionally in fixed installations using a 110/230 AC power
supply. Also primary lithium or alkaline cells (6 ... 9 V) as well as
external DC supply (8 ... 14 VDC recommended, 30 VDC max) alone
can be used as the main power source for MAWS.