Chapter 4 ____________________________________________ Basic Use of Lizard Setup Software
VAISALA______________________________________________________________________ 121
available. Reports can also be sent to virtual COM ports; for details on
virtual COM ports and using them with reports, refer to Vaisala
HydroMet™ Data Collection Platform User’s Guide, Volume 3.
To connect reports to communication ports, proceed as follows:
1. Select the report from the Available reports list box by clicking on
it.
2. Select the port you want to send it through by clicking on the
desired row in the Port/Device list box.
3. Click the linking button.
4. The linked report-port pair appears in the Reports sent/
Destination list box. A corresponding Configure frame also
appears on the left of the view.
Lizard Setup Software makes a distinction between communication
ports and devices. Ordinarily, only the communication port through
which the report is sent is listed under Destination. However, if the
final destination is an actual device controlled by the QML logger, then
the name of the device is displayed under Destination instead of the
communication port.
Disconnecting Reports from
Communication Ports
To disconnect reports from communication ports, proceed as follows:
1. Select the desired row from the Reports sent/Destination list box.
The corresponding rows in the Available reports list box and the
Port/Device list box are also highlighted.
2. Click the Unlink button.
The report-port pair is unlinked and no longer appears in the Reports
sent/Destination list box.