Vaisala HydroMet User's Guide Page 139

  • Download
  • Add to my manuals
  • Print
  • Page
    / 218
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 138
Chapter 4 ____________________________________________ Basic Use of Lizard Setup Software
VAISALA______________________________________________________________________ 137
Table 20 Alarms
Col # Column Label Content
1 Name Alarm name
2 Interval [s] Condition test interval in seconds
3 Source Source for the tested variable
4 Variable Name of the tested variable
5 Target Act. Target report or the log group when an alarm
becomes or already is active
6 Target Deact. Target report or the log group when an alarm
becomes or already is inactive
7 Test Alarm condition in comparison to minimum and
maximum values:
- Below min = Below minimum
- Above max = Above maximum
- Outside min - max = Between minimum and
maximum
- Between min - max = Between minimum and
maximum
8 Min Value for the minimum limit
9 Max Value for the maximum limit
10 Limit Source Source for the limit when an other variable is
used as the limit
11 Limit Variable Name of the limiting variable when an other
variable is used as the limit
Table 21 Timed Events
Col # Column Label Content
1 Timer # Timer number. Use this as the first parameter
<tevId> in ctev command when changing timer
intervals through the service or remote
command interface:
ctev <tevId> <interval>
2 Target Target component name
3 Event Triggered event type
4 Interval [s] Triggering interval in seconds
5 Synch [s] Synchronization time in seconds counted from
00:00:00 hours
6 Timezone Time zone: Local or UTC (formerly Greenwich
mean time)
7 Timer type Timer type: Periodic or Single shot
Page view 138