Technical Data
Operating Environment, Both Models
Mechanical durability Up to +180 °C (+356 °F) for DMT345
of probes Up to +350 °C (+662 °F) for DMT346
for transmitter body -40 ... +60 °C (-40 ... +140 °F)
with display 0 ... +60 °C (32 … +140 °F)
Storage temperature range -55 ... +80 °C (-67 … +176 °F)
Pressure range for probes slight pressure difference (~ 200 mbar)
Measured gases non corrosive gases
Complies with EMC standard EN61326-1, Electrical equipment for
measurement, control and laboratory use - EMC requirements;
Industrial environment.
Measured Variables DMT346
DEWPOINT DMT346
Sensor Vaisala DRYCAP
®
180S
Measurement range -25 ... +100 °C (-13 ... +212 °F) Td
Accuracy ±2 °C (±3.6 °F) Td
See the accuracy graph below
Dewpoint accuracy vs. measurement conditions
Response time 63 % [90 %] flow rate 1 l/min and 1 bar pressure
from dry to wet 5s [10 s]
from wet to dry including auto-calibration 45s [5 min]
MIXING RATIO DMT346
Measurement range (typical) 0 ... 1000 g/kg (0 ... 7000 gr/lbs)
Accuracy (typical) ±12% of reading
Inputs and Outputs, Both Models
Operating voltage 10 ... 35 VDC, 24 VAC
with optional power supply module 100 ... 240 VAC 50/60 Hz
Default start-up time
initial reading after power-up 3 s
full operation after sensor Purge and Autocal about 6 min
Power consumption @ 20 °C (U
in
24 VDC)
U
out
2x0 ... 1V/0 ... 5V/0 ... 10V max 25 mA
I
out
2x0 ... 20mA max 60 mA
RS-232 max 25 mA
display and backlight + 20 mA
during sensor purge + 110 mA max
Analog outputs (2 standard, 3rd optional)
current output 0 ... 20 mA, 4 ... 20 mA
voltage output 0 ... 1 V, 0 ... 5 V, 0 ... 10 V
Accuracy of analog outputs at 20 °C ± 0.05 % full scale
Temperature dependence of the
analog outputs ± 0.005 %/°C full scale
External loads
current outputs R
L
< 500 ohm
0 ... 1V output R
L
> 2 kohm
0 ... 5V and 0 ... 10V outputs R
L
> 10 kohm
Max wire size 0.5 mm
2
(AWG 20) stranded
wires recommended
Digital outputs RS-232, RS-485 (optional)
Protocols ASCII commands, MODBUS RTU
Service connection RS-232, USB
Relay outputs 2+2 pcs (optional) 0.5 A, 250 VAC, SPDT
Ethernet interface (optional)
Supported standards 10BASE-T, 100BASE-TX
Connector 8P8C (RJ45)
IPv4 address assignment DHCP (automatic), static
Protocols Telnet, MODBUS TCP/IP
WLAN interface (optional) DHCP (automatic), static
Supported standards 802.11b
Antenna connector type RP-SMA
IPv4 address assignment DHCP (automatic), static
Protocols Telnet, MODBUS TCP/IP
Security WEP 64/128,WPA
WPA2/802.11i
Authentication / Encryption (WLAN)
Open / no encryption
Open / WEP
WPA Pre shared key / TKIP
WPA Pre shared key / CCMP (a.k.a. WPA2)
Optional data logger with real-time clock
Logged parameters max. four with trend/min/max values
Logging interval 10 sec (fixed)
Max. logging period 4 years 5 months
Logged points 13,7 million points per parameter
Battery lifetime min. 5 years
Display (optional) LCD with backlight, graphic trend display
Display menu languages English, French, Spanish, Chinese,
German, Japanese, Russian, Swedish, Finnish
Mechanics, Both Models
Cable bushing M20x1.5 For cable diameter
8 ... 11mm/0.31 ... 0.43"
Conduit fitting (optional) 1/2"NPT
User cable connector (optional) M12 series 8- pin (male)
option 1 with plug (female) with 5 m /16.4 ft black cable
option 2 with plug (female) with screw terminals
USB-RJ45 Serial Connection Cable part. no 219685
Probe cable diameter 5.5 mm
Probe cable length 2 m, 5 m or 10 m
Housing material G-AlSi 10 Mg (DIN 1725)
Housing classification IP 65 (NEMA 4X)
Housing weight 1.2 kg