VAISALA ______________________________________________________________________ 117
Table 31 General
Property Description/Value
Heating No heating: 0 W
Average heating power 30 W
Peak transducer heating power: 40 W
Average transducer and array arm heating:
150W
Peak transducer and array arm heating: 200
W
Operating temperature
-10 ... +60 °C
-40 ... +60 °C
-55 ... +70 °C
Operating voltage
Absolute maximum
9 ... 36 VDC
40 VDC
Heating voltage
Typical ranges
Absolute maximum
24 ... 36 VDC
40 VDC
IP class IP66/IP67
Material
Body
Transducers
Mounting kit
stainless steel AISI316
silicone
stainless steel AISI316
Dimensions
Height
Width
Depth
350 mm
250 mm
285 mm
Weight WMT700 Wind Sensor: 1.9 kg
Mounting adapter: 0.3 kg
Fix70 Mounting Kit 1.4 kg
Connector Hummel 7.106 series
NOTE
Any temporary element or object (such as snow, ice, or a bird) blocking
the measurement path between the ultrasonic transducer heads may affect
the wind measurement accuracy or even invalidate the output data.