Appendix D ___________________________________________________Configuration Parameters
VAISALA ______________________________________________________________________ 129
APPENDIX D
CONFIGURATION PARAMETERS
This appendix lists WMT700 Configuration parameters.
Parameter
Name
Default
Value
Allowed Values Units Description
address A String with a
maximum of 40
characters.
Address for WMT700. Note that the SDI-
12, ASCII, NMEA Extended, ASOS and
MES12 profiles use the first character
only.
SDI-12 only uses digits 1 … 9.
aoErrValue 1000 0 … 32000 V, mA,
Hz
Value for analog output if wind
measurement fails.
aout1_g
aout2_g
1 0 ... 100 Gain for AOUT1 (wind speed) and
AOUT2 (wind direction).
aout1_o
aout2_o
0 -10000 … 10000 Offset for AOUT1 and AOUT2.
aout1maxv
aout2maxv
32000 0…32000 V, A,
Hz
Analog output maximum value for
AOUT1 and AOUT2. The output is fixed
to this value. The unit depends on analog
output mode.
aout1minv
aout2minv
0 0…32000 V, A,
Hz
Analog output minimum value for AOUT1
and AOUT2. The output is fixed to this
value. The unit depends on the analog
output mode.
aout1mode 3 0 = current
1 = voltage
2 = frequency
3 = disabled
Analog output mode for AOUT1.
aout2mode 7 4 = current
5 = voltage
6 = potentiometer
7 = disabled
Analog output mode for AOUT2.
autoInt 1 0.25 ... 1000
Resolution: 0.25
s Automatic message interval in seconds.
This parameter affects both serial
communication and analog output.
Do not select a message interval that is
shorter than the time it takes to send a
data message.
autoPort 1 1 = COM1 port
2 = COM2 port
Serial port to which WMT700 sends
automatic data messages.
autoSend 0 0 = automatic
messages disabled
1 … 99
Automatic data message number.
Selects the data message format for
automatic messages.