USER'S GUIDE____________________________________________________________________
36 __________________________________________________________________ M211095EN-C
Figure 11 below. Note that you should follow application-specific
installation guidelines.
When mounting two WMT700s at the same height, make sure that there
is a minimum of 10 meters of distance between the two devices. If the
difference in the height of the sensors is at least 0.5 meters, it is enough
to have a minimum distance of 2 meters between the two devices to
avoid possible acoustical interference between them. See Figure 13 on
page 38.
WARNING
If ice or snow accumulates on WMT700 or the mast, it can fall and cause
injury to persons below.
1001-016
Figure 11 Recommended Location for WMT700 in Open Area
where:
h = Height of a building or other high structure.
r = Distance from a building or other high structure.
y = Distance from the vertical mast.
z = Diameter of the vertical mast.