Chapter 5 _________________________________________________________________ Operation
Table 38 Monitoring Items for Data Messages
Item
Description
\er
Status code. The code is a decimal number. Each bit
corresponds to a status flag. For a list of the bits, see section
Status Flags on page 123
\fb
0 = No error
1 = Blocked sensor
\fh
0 = No error
1 = Heater failure. Incorrect heater resistance.
\fs
0 = No error
1 = Wind speed exceeds operating limits
2 = Sonic temperature exceeds operating limits
3 = Wind speed and sonic temperature exceed operating limits
\ft
This value indicates temperature sensor failures when converted
to binary format:
Bit 0 = Temperature sensor 1 failure
Bit 1 = Temperature sensor 2 failure
Bit 2 = Temperature sensor 3 failure
\fv
0 = No error
1 = Supply voltage (Vh or Vi) too high
2 = Supply voltage (Vh or Vi) too low
\pa
Average heating power
\ra
Heater resistance
\ta
Transducer temperature
\ti
Internal temperature
\vh
Heater voltage
\vi
Supply voltage
Example 1:
In this example a new data message with identification number 1
is defined. The items included in the message are average wind
speed, average wind direction, and supply voltage.
S msg1,$\ws,\wd,\vi\cr\lf
When the above message is polled, WMT700 sends the following
data if the average wind speed is 5 m/s, the average wind
direction is 128 degrees, and the supply voltage is 23.4:
$05.00,128,23.4<CR><LF>