Chapter 8 _____________________________________________________________ Technical Data
Table 61 General
Average heating power 30 W
Peak transducer heating power: 40 W
Average transducer and array arm heating:
150 W
Average transducer, arm, and body heating:
250 W
Peak transducer, arm, and body heating: 350 W
-40 ... +60 °C
9 ... 36 VDC; see details in Table 26 on page 84
Body
Transducers
Stainless steel AISI316
Silicone
Height
Width
348 mm
250 mm
WMT700 Wind Sensor: 1.8 kg
Mounting adapter: 0.3 kg
Fix70 Mounting Kit 1.4 kg
NOTE
In maritime environments, the normal input voltage ranges are:
… 30 VDC (-10% … +30%) and heating voltage
… 30 VDC (-10% … +30%), as defined in the maritime standard
60945.
NOTE
Any temporary element or object (such as snow, ice, or a bird) blocking
the measurement path between the ultrasonic transducer heads may affect
the wind measurement accuracy or even invalidate the output
data.