Chapter 5 _________________________________________________________________ Operation
WMT700 responds to the Wx command with a 19-character
fixed-length data message. For more information, see Table 51
below.
Table 51 WS425 A/B ASCII Data Message
Character
Description
1
02H (<STX>, start of transmission)
2
W
3
Averaging in seconds
4
Status:
P = Pass
F = Fail
5
Wind direction (most significant digit)
6
Wind direction (middle digit)
7
Wind direction (least significant digit)
8
Wind speed (most significant digit)
9
Wind speed (next digit)
10
Wind speed (next digit)
11
Wind speed (least significant digit)
12
. (dot character)
13
Wind speed (tenth digit)
14
Wind speed unit:
M = Miles per hour
K = Knots
L = Kilometers per hour
T = Meters per second
15
Checksum (most significant digit). For more information, see the
note below
16
Checksum (least significant digit)
17
03H (<ETX>, end of transmission)
18
CR (carriage return)
19
LF (line feed)
NOTE
The checksum is calculated from the characters from position 2 to 14.
The accumulator initializes at 0 with the addition of the byte value. The
checksum has a range of 0H … FFH.