Vaisala WINDCAP WS425 User's Guide Page 189

  • Download
  • Add to my manuals
  • Print
  • Page
    / 221
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 188
Chapter 7 ____________________________________________________________ Troubleshooting
10. Press # on your keyboard and hold down the key for at least
five seconds. WMT700 responds by sending the following
string:
Ok
Restoring COM1 and COM2 settings…
Updating the settings will be completed in a few seconds.
When the operation is done, WMT700 sends the following
response:
Done. Rebooting…
WMT700 has now applied the settings and will reboot using
the new settings. The restored settings are shown in Table
57 below.
11. Before you start configuring new values to WMT700, you
need to apply the new settings to HyperTerminal. In the
Call menu, click Disconnect to close the connection.
12. On the File menu, click Properties.
13. In the Properties dialog, click Configure.
14. Select 9600 in the Bits per second combo box.
15. Close the Properties window.
16. On the Call menu, click Call.
Table 57 Restored Serial Port Settings
Parameter Name
Default Value
Description
com1_baud
com2_baud
4
4 = 9600 bauds per second
com1_data
com2_data
8
Number of data bits
com1_delay
com2_delay
20
Response delay in milliseconds
com2_interf
0
0 = RS-485
com1_parity
com2_parity
0
0 = None
com1_protocol
com2_protocol
0
WMT700 protocol
com1_stop
com2_stop
1
Number of stop bits
The serial port settings have now been restored to known values.
You can send the OPEN command and start configuring
WMT700. For information on the configuration commands, see
section Configuration on page 110.