Vaisala HMD70U Service Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 162
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
12
HMT337 Humidity and Temperature Transmitter
for High Humidity Applications
The Vaisala HUMICAP
®
Humidity
and Temperature Transmitter
HMT337 is delivered in one of three
configurations:
• Basic:non-warmedprobefor
moderate humidities
• Withawarmedprobe:fornear-
condensing conditions and dew
point measurement
• Withawarmedprobeandan
additional temperature sensor: for
near-condensing conditions and
relative humidity measurement
True Humidity Readings
in Conditions of
Condensation
The Vaisala unique warmed
probe provides fast and reliable
Features/Benefits
For high-humidity applications
in industry and meteorology
Warmed probe for superior
performance in condensing
environments
Small, stainless steel, vapor-
tight remote probe
For temperatures
-70 ... +180 °C (-94 ... +356 °F)
The HMT337 is the ideal transmitter for the most demanding process and
meteorological measurements.
measurement in environments where
humidity is near saturation. The
warming prevents condensation from
forming on the sensor.
As the probe is warmed, the humidity
level inside it stays below the ambient
level. With accurate temperature
measurement, the ambient dewpoint
can be calculated precisely.
If the relative humidity value is
needed, an additional temperature
sensor is used. The measured
ambient temperature provides
the compensation for calculating
relative humidity and other humidity
parameters.
Many Ways to Install
A tight installation through a process
wall can be achieved with Swagelok
®
fittings. Meteorological installation
kits for outdoor installations and duct
installation kits are also available.
Duct installation kit
Technical Data
Temperature measurement range
-70 ... +180 °C (-94 ... +356 °F)
Accessories
Cable gland and AGRO HMP247CG
Duct installation kit (RH probe) 210697
Duct installation kit (T probe) 215003
Swagelok fittings (NPT and ISO)
for both RH and T probes
Solar radiation shield DTR502B
Meteorological inst. kit HMT330MIK
PC software + cable 215005
USB-RJ45 Serial Connection Cable 219685
Connection cable for HM70 211339
Wall mounting plate (plastic) 214829
Pole installation kit 215108
Rain shield 215109
DIN rail installation set 215094
Dimensions
Dimensions in mm (inches)
ø 12 (0.47)
37.5 (1.48)
79.5 (3.13)
99.5 (3.92)
M9×1
Page view 13