Operating Environment
Temperature *) -40 ... +60 °C (-40 ... +140 °F)
Relative humidity 0 ... 100 %RH
Pressure *) 0 ... 50 bar
a
(725 psia)
Sample flow rate no effect for measurement accuracy
*) For extended temperature down to -40 °C (-40 °F) or pressure
up to 50 bar
a
(725 psia) the supply voltage must be 24 ... 28 VDC.
Outputs
Analog output (scalable) 4 ... 20 mA (3-wire), 0 ... 1 V/5 V
Resolution for current output 0.002 mA
Resolution for voltage output 0.3 mV
Typical temperature dependence 0.005% of span / °C
Connector 4-pin M8 (IEC 60947-5-2)
connection cable with snap-on or thread locking available
RS232 serial line for service use with DMT142RS cable
General
Sensor Vaisala DRYCAP
®
180D
Measured gases non-corrosive gases
(SF
6
gas with special model)
DEW POINT ACCURACY VS. MEASUREMENT CONDITIONS
Dew point accuracy range for the extended version. Standard
version with dotted line.
Response time 63% [90%] at +20 °C gas temperature and 1 bar
pressure
-60 -> -20 °C T
d
(-76 -> -4 °F T
d
) 5 s [10 s]
-20 -> -60 °C T
d
(-4 -> -76 °F T
d
) 45 s [10 min]
PPM VOLUME CONCENTRATION
Measurement range 70 ... 200 000 ppm
Accuracy at +20 °C (+68 °F), 1013 mbar 7.3 ppm + 9.2% of reading
Accessories
Connection cable for DM70 211917ZZ
Service cable for serial line DMT142RS
Sampling cells
basic sampling cell DMT242SC
with Swagelok 1/4" male connectors DMT242SC2
with quick connector and leak screw DSC74
two-pressure sampling cell DSC74B
cooling/venting coil DMCOIL
See DM70 / Portable Sampling Systems and Sampling Cells for
further information about sampling cells available
Loop powered external display 226476
Dewpoint temperature (°C)
Temperature of measured gas (°C)
Dewpoint accuracy range for the extended version. Standard version with dotted line.
0
40
-60
-80
10
20
30
50
60
70
-10
-20
-30
-50
-40
-70
80
0
-10
-20
-30
-40
10
20 30
40
50
60
Dewpoint measurement range lower limit
Accuracy ±3 °C Td
or better
Water vapor saturation line
Accuracy ±4 °C Td
Std version ±3 °C range
or better
Not recommended area
for continuous measurement
AW24
G1/2” ISO 228/1
58 22.5
92.5
Ø12
Ø28
Dimensions
in mm
Recommended calibration interval
to confirm the specified accuracy 2 years
Operating voltage with voltage output 12 ... 28 VDC
Operating voltage with current output 18 ... 28 VDC
Supply current
normal measurement 10 mA + load current
during self-diagnostics max. 220 mA pulsed
Load for current output max. 500 ohm
Load for voltage output min. 10 kohm
Housing material stainless steel body (AISI316L) plastic
cap(ABS/PC)
Sensor protection stainless steel sintered filter
Mechanical connection G1/2” ISO 228-1 thread
with bonded seal ring (U-seal)
Housing classification IP64 (NEMA 3S)
Storage temperature range -40 ... +80 °C (-40 ... +176 °F)
Weight 118 g (4.16 oz)
Complies with EMC standard EN61326-1, Electrical equipment for
measurement, control and laboratory use - EMC requirements;
Industrial environment.