Vaisala WAA151 Installation Manual Page 102

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 101
Installation Manual __________________________________________________________________
100 __________________________________________________________________ M010114en-B
4. Connect the signal cable to the connector Sol. Rad. at the
bottom of the equipment enclosure (see section Connecting
Cables on page 129).
CM11
See installation of CM6B on page 99.
QMN101
It is recommended to install the sensor at least 1.5 meters above the
surface in order to avoid shading effects and to promote spatial
averaging. Install the sensor as follows:
1. Attach the radiometer (6) to the extension arm (5). For the
numbers, see Figure 93 below.
2. Attach the sensor's extension arm (5) with the adapter (3).
3. Lead the cable (2) through the sensor arm (1).
4. Use the bolts (4) to attach the mounting piece (3) to the sensor
arm (1).
5. After you have installed the sensor, connect the signal cable to
NET Rad. connector at the bottom of the equipment enclosure
(see section Connecting Cables on page 129).
0202-012
Figure 93 Installing QMN101 Net Radiometer
DSU12
1. Install the sunshine duration sensor (see Figure 94 on page 101).
2. Pull the sensor cable close to the equipment enclosure. Cut the
cable to a proper length. Thread the cable through the connector
parts in the indicated order 1-2-3-4 (see Figure 87 on page 96).