Vaisala WAA151 Installation Manual Page 97

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 96
Chapter 4 ________________________________________________________________ Installation
VAISALA ________________________________________________________________________ 95
RG13H
1. Loosen the three screws securing the outer tube to the base and
lift off the outer tube.
2. Connect the output signal cable through the grommet and into
the terminal block provided on the underside of the base. Then
seal it using a silicone rubber compound.
3. Place the base onto the site, using a spirit level with the three
leveling screws. Secure the locknuts.
4. It is advisable to permanently secure the base using the two
holding lugs provided. These accept either 9.5 mm or 3/8"
rawlbolts.
5. Carefully remove the restriction to bucket movement, fitted for
transit purposes, and check that the bucket does pivot.
6. Replace the outer tube and secure it into position.
DRD11A
1. Install the DRD11A Rain Indication Sensor on DKPSUP (see
Figure 86 below).
0105-062
Figure 86 DRD11A Installed on Support Arm
2. Pull the sensor cable close to the equipment enclosure. Cut the
cable to a proper length. Thread the cable through the connector
parts in the indicated order 1-2-3-4 (see Figure 87 on page 96).
Page view 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 132 133

Comments to this Manuals