Installation Manual __________________________________________________________________
66 ___________________________________________________________________ M010114en-B
0002-001
Figure 58 Siting the Station
Air Temperature and Relative Humidity
NOTE
The radiation shield is important in protecting the sensor from direct
sunlight and must always be used.
For mast installations, the height of the sensor should be set to 1.5 to 2
meters. In the northern hemisphere, the sensor should usually be
placed on the northern side of the tower. Avoid the following
installation sites to ensure correct measurements: shaded areas, steep
slopes, heat sources, swamps, high vegetation and places that might
hold water after rains.
Precipitation
Rain gauge is installed on the ground, on a base plate, or on a separate
stand near the MAWS enclosure.
The orifice of the gauge must be in a horizontal plane, open to the sky,
and above the level of in-splashing and snow accumulation. In
general, objects should not be closer to the gauge than a distance twice
their height above the gauge orifice.