CM6B
0105-022
Figure 25 CM6B Pyranometer
CM6B Pyranometer is an ISO 9060 first class pyranometer. CM6B
incorporates a 64-thermocouple sensor, which is rotationally
symmetrical and housed under K5 glass domes. A white screen
prevents the body of the pyranometer from heating up.
CM11
0105-023
Figure 26 CM11 Pyranometer
CM11 Pyranometer is an ISO 9060 secondary standard pyranometer.
CM11 incorporates a 100-thermocouple sensor, which is rotationally
symmetrical and housed under K5 glass domes. A white screen
prevents the body of the pyranometer from heating up.