Vaisala MAWS201 User's Guide Page 122

  • Download
  • Add to my manuals
  • Print
  • Page
    / 196
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 121
User's Guide _______________________________________________________________________
120 __________________________________________________________________ M210243en-A
Log Data Format
A log entry is generated at the time described in the setup file. When
entries are retrieved with the logshow command, the produced output
includes two parts: the header and the log entry information.
An example of a log query shows 4 entries of logged items 2, 3 and 4
starting at 10 o'clock on December 28, 1998:
/Log > logshow L1 d981228104234
Stat17:DP1_AVG Stat18:RH1_AVG Stat19:TA1_AVG
1998-12-28 10:00:01 V----- 1.5986 V----- 25.276 V----- 22.381
1998-12-28 10:01:01 V----- 1.5657 V----- 25.216 V----- 22.386
1998-12-28 10:02:01 V----- 1.5584 V----- 25.195 V----- 22.398
1998-12-28 10:03:01 V----- 1.5401 V----- 25.166 V----- 22.398
The header information shows the log parameter number (17, 18 and
19) and the variable name (average dew point, - relative humidity and
- temperature).
The log entry information includes the time tag (date and time) of the
entry, the status, and the value of the logged measurement/calculation.
Table 23 Log Entry Status
Status Indicator Status Description
-I----- Invalid Value may be outside the set
scale; i.e., set climatological
limits or step change
validation.
-I--N- Invalid; not available No measurements done yet.
V----- Valid (normal) Measurement / calculated
value available normally.
Controlling Logging
Logging is automatically on if it has been defined in the setup and if it
has not been stopped. The logging needs to be stopped when:
- Today's log file is retrieved.
- A sensor is replaced (if some invalid log items can be tolerated,
stopping is not necessary).
To see logging status, type logstatus <group_id>. To stop or start
logging type logstop/loggo <group_id>.