Chapter 7 _____________________________________________________________ Technical Data
VAISALA _______________________________________________________________________ 179
Sensors
Wind Sensors
Table 47 QMW101/QMV110 Combined Wind Sensor
Specifications
Property Description/Value
Measurement range 0.5 ... 60 m/s (anemometer)
0 ... 360 ° (vane)
Accuracy (anemometer)
± 0.3 m/s (< 10 m/s)
< 2 % (> 10 m/s)
Accuracy (vane)
< ± 3 °
Threshold < 1.0 m/s
Distance constant (anemometer) 2 m
Delay distance (vane) 0.6 m
Operating temperature range -40 ... +55 °C
Dimensions (h × w)
265 × 360 mm
Weight 360 g
Air Temperature and Relative Humidity Sensor
Table 48 QMH101 Air Temperature and Relative Humidity
Sensor Specifications
Property Description/Value
Range (Temperature)
-40 … +60 °C
Range (RH) 0 ... 100 %
Accuracy (Temperature)
< ± 0.3 °C
Accuracy (RH)
± 2 %, 0 ... 90 %
± 3 %, 90 ... 100 %
Pressure Sensor
Table 49 PMT16A Pressure Sensor Specifications
Property Description/Value
Accuracy
± 0.3 hPa incl. one year drift (with factory
calibration)
Pressure range 600 ... 1100 hPa
Temperature range
-40 ... +60 °C (operating)
Comments to this Manuals