Vaisala MAWS201 User's Guide Page 87

  • Download
  • Add to my manuals
  • Print
  • Page
    / 196
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 86
Chapter 3 ________________________________________________________________ Installation
VAISALA ________________________________________________________________________ 85
CAUTION
DO NOT drive or press probes directly into soil of unknown
composition.
DO NOT bend or flex probes during insertion or extraction.
DO NOT attach unapproved electrical devices or test equipment to
the probe.
DO make a pilot hole prior to each probe insertion, unless the soil
consists of homogenous, loose sand.
DO inspect and clean the probe connector prior to each use.
Note that probe warranty is void if a hammer or unapproved tool is
used to drive the probe into the soil.
3. Finally, connect the signal cable to the connector at the lower
base of the tube. For more information, see section Connecting
Cables on page 71.
Installing Soil Moisture Sensor
To install the ML2x sensor, follow the procedure below:
1. The sensor can either be inserted or buried into the soil as shown
in Figure 81 below and Figure 82 on page 86.
0105-087
Figure 81 ML2x Soil Moisture Sensor
Page view 86