Installation Manual __________________________________________________________________
86 ___________________________________________________________________ M010114en-B
The following numbers refer to Figure 74 on page 85:
1 Bird spikes
2 Sensor body
3 3/16 inch Hex-socket bolt
4 Adapter
5 Clamp
If the bird spikes are not sufficient to keep animals away from the
sensor arms, the sensor may also be mounted arms down. This
installation method requires the use of a sensor arm WAC425. The
sensor arm protects the cable connector from rain.
Below is the mounting procedure for the sensor arm.
1. Remove the hex-socket bolt, if still attached to the sensor body,
shown in Figure 74 on page 85 (use a 3/16-inch Allen key).
2. Pull the cable through the horizontal pipe of the sensor arm so
that the cable connector remains inside the vertical pipe.
3. Connect the cable to the sensor.
4. Attach the sensor to the vertical pipe of the sensor arm. Insert
the hex-socket bolt.
5. Use the clamps to attach the sensor arm to a 60 mm diameter
tube.
Wind direction alignment procedure
One transducer arm is permanently marked with "N " for north and a
second transducer arm is permanently marked with "S " for south.
NOTE
You might find the alignment procedure easier if you mark (e.g., with
paint or colored tape) the sensor body to indicate north and south so
that you can see it from the ground.
Complete the following steps to aim the wind sensor when using the
WAC425 sensor arm for mounting.
1. Use the compass to determine if the horizontal pipe of the sensor
arm is properly aligned to north and south. The sensor end
should face north.
2. If the alignment is not correct, lower the tower.
Page view 87