Installation Manual __________________________________________________________________
88 ___________________________________________________________________ M010114en-B
Air Temperature and Relative Humidity Sensor
Figure 76 QMH102 Probe and the Radiation Shield
Install the QMH102 Temperature and Relative Humidity Sensor in the
following way:
1. Install the radiation shield with the support on the mounting arm
using the two screws. See Figure 62 on page 74.
2. Slide the temperature and humidity probe into the shield.
3. Tighten the fastening ring.
4. Guide the sensor cable down along the mast to the enclosure.
5. Connect the signal cable to MAWS (see section Connecting
Cables on page 129).