130 __________________________________________________________________ M210243en-A
removes the source file.
open Opens the terminal connection.
pslevel
pslevel [meters]. To see the current pressure sensor level, type pslevel. To
change the pressure sensor level, type pslevel and the new pressure
sensor level in meters from the station altitude.
rd rd <path> removes directory
rep rep <report_name> shows contents of a report report_name. E.g. "rep
MyRep0".
reset reset [delay (seconds)] resets MAWS (warm boot). If the delay time is not
typed, MAWS resets immediately.
serial serial <port_number> [speed] [parity] [bits] [stop]. To see the settings of the
port number 0, type serial 0. To change the settings, type serial 0 and the
new parameters. E.g. "serial 0 9600 N 8 1". Available ranges/options:
Speed 300-19200, Parity N/O/E, Bits 7/8, Stop 0/1.
SLEEP
Sets MAWS in low power-state. Use the SLEEP command to reduce
power consumption when storing the station for a few days (maximum
period 1 month). Tip the spoon of the rain gauge to wake up MAWS.
MAWS can also be woken up by pressing the reset button.
NOTE! The SLEEP command must be written in upper case.
sname
sname [station_name]. To see the current station name, type sname. To
change the name, type sname and the new name. If the station name
begins with a digit or contains a space, the name must be in quotes e.g.
sname "Vaisala MAWS".
spclear spclear <parameter/ALL> clears a static parameter/all parameters.
NOTE! This command clears QMS101 and QMN101 sensitivity settings
and is not usually needed.
spset spset [parameter] [value] sets a value to a static parameter. To see a list of
static parameters, type spset.
NOTE! This command is not usually needed.
SYSINFO SYSINFO gives information on the system.
NOTE! The command must be written in upper case.
time
time [HH MM SS YY MM DD]. To see the current time, type time. To
change the current time, type time and the new time. E.g. "time 14 10 00".
To change the current date, type time and the new time and date e.g. "time
14 10 00 98 12 31".
timezone timezone [hours] sets the time difference from UTC. To see the time zone,
type timezone. To set the time zone, type e.g. "timezone 2".
userlevel
userlevel [level <set/clear>]command is used to protect system from
unauthorized use. It provides three password protected access levels to
shell commands as well as to the visibility of system data. By default, the
user levels are not in use.
verify verify <source file> <destination file> verifies file(s)
warnings
warnings [clear]. To see active warnings, type warnings. To clear active
warnings, type warnings clear. Warnings indicate that there are some
problems in the software. See the Troubleshooting chapter on page 153 for
more information.
winddircal0 winddircal0 [direction]. Set the direction in degrees to align the wind vane.
Type for example "winddircal0 360" (north).
zr Zmodem receive command is needed when transferring the setup file to
MAWS.
zs zs <file_name>. Sends a file from MAWS using Zmodem protocol.